Water(ground)source heat pump

——

Add Time: 2018-10-24 13:38:58
Recommendation:

介 绍

——

Print       Small   Middle   Big

nHigh efficiency  

Make full use of the geothermal energy, 1 copy of electricity can make more than 4 copies of cooling and heating capacity.

nLow operation expense  

The units can save around 50% of operation expense compared with traditional central air conditioning.

nInvestment saving  

Saving cooling towers, boilers and area of structure.

nGreen and safe  

Eliminating the hidden dangers of combustion or explosion, no harmful gases released.

nReliable operation  

The system is immune to external climate change with stable operation and long service life.

nBeautiful and comfortable  

The system operates quiet and maintains the beautiful appearance of building.

nSimple maintenance  

Simple system with few trouble points, no need special personnel to manage.

nIndependent counting system  

Household-based and area-based installation and control achieve independent counting function.

nFlexible in usage  

The unit is combination of cooling, heating and hot water supplying.

blob.png

Variable cooling conditions performance modified coefficient table

Chilled water outlet temperature ℃

Cooling water inlet temperature ℃

18

20

25

30

32

35

Cooling capacity

Input power

Cooling capacity

Input power

Cooling capacity

Input power

Cooling capacity

Input power

Cooling capacity

Input power

Cooling capacity

Input power

5

1.010

0.868

0.971

0.910

0.933

0.971

0.892

1.033

0.857

1.102

0.833

1.152

6

1.042

0.889

1.025

0.923

0.971

0.993

0.922

1.058

0.889

1.113

0.873

1.170

7

1.069

0.901

1.055

0.932

1.000

1.000

0.950

1.081

0.920

1.145

0.890

1.188

8

1.121

0.922

1.082

0.951

1.040

1.009

0.993

1.111

0.949

1.148

0.917

1.198

9

1.157

0.932

1.130

0.969

1.082

1.021

1.019

1.122

0.982

1.161

0.954

1.208

10

1.205

0.951

1.172

0.988

1.111

1.030

1.058

1.141

1.031

1.172

0.993

1.221

Variable heating conditions performance modified coefficient table

Hot water outlet temperature ℃℃

Heat source water inlet   temperature ℃

20

15

10

5

0

-5

Heating capacity

Input power

Heating capacity

Input power

Heating capacity

Input power

Heating capacity

Input power

Heating capacity

Input power

Heating capacity

Input power

40

1.244

1.055

1.140

0.982

1.079

0.931

1.023

0.921

0.948

0.911

0.891

0.900

42

1.219

1.087

1.135

1.022

1.048

0.966

0.990

0.954

0.935

0.944

0.842

0.924

43

1.188

1.111

1.123

1.039

1.032

0.988

0.977

0.966

0.918

0.948

0.833

0.932

45

1.168

1.152

1.094

1.122

1.000

1.000

0.950

0.981

0.888

0.967

0.825

0.954

48

1.113

1.201

1.062

1.161

0.970

1.123

0.925

1.080

0.872

1.022

50

1.063

1.272

1.012

1.210

0.935

1.161

0.883

1.113


On AWater Cooled Screw Chiller
NextModular air cooled chiller(heat pump)

Products

A model of China's practical, environment-friendly central air conditioning